Doosan

GENSET MODEL ESP
(kVA/kW)
PRP
(kVA/kW)
ENGINE MODEL CYL. PDF DESIGN SPECIFICATIONS; High quality, reliable and complate power unit,Compact design,Easy start and maintenance possibility,Every generating set is subjected to a comprehensive test programme which includes full load testing and checking and providing of all control and safety shut down functions testing,Full engineered with a wide range of options and accessories:Canopy,soundproof and on road trailer
ENGINE;  DOOSAN heavy duty diesel engine, Four stroke, water cooled, 1500 rpm, turbocharged, charge air cooled Direct injection fuel system, 24 VDC starter and charge alternator,  Replaceable fuel filter, oil filter and dry element air filter,Cooling radiator and fan, Starter battery (with lead acid) including Rack and Cables, Flexible fuel connection hoses and oil sump drain valve, Industrial capacity exhaust silencer and steel bellows,  Jacket water heater (at automatic models) Operation mauals and circuit diagram documentsALTERNATOR; Brushless, single bearing system, 4 poles, Insulation class H, Standard degree of protection IP21, Self-exciting and self-regulating, Impregnation with tropicalised epoxy varnish, Solid state Automatic Voltage RegulatorBASE FRAME; The complete genset is mounted as whole on a heavy-duty fabricated, steel base frame. Antivibration pads are fixed between the engine/ alternator feet and the base frame. Base frame design incorporates an integral fuel tank. The generating set can be lifted or carefully pushed / pulled by the base frame,Lifting eyes allow easy transportation by a crain. Dial type fuel gauge and drain plug on the fuel tank.CANOPY; All canopy parts are designed with modular principles. without welding assembly.Doors on each side. All metal canopy parts are painted by electrostatic. Exhaust silencer is protected against environment influencespolyester  powder paint. Thermally insulated engine exhaust system.  Emergency stop push button installed outside of canopy Easy lifting and moving  Easy mainteneance and operation
RD220 220 176 200 160 P086TI 6L  
RD275 275 220 250 200 P086TI 6L  
RD330 330 264 300 240 P126TI-II 6L  
RD410 410 328 375 300 P158LE-1 8V  
RD500 500 400 450 360 P158LE 8V  
RD550 550 440 500 400 P180LE 10V  
RD600 600 480 500 400 P180LE 10V  
RD660 660 528 611 489 P222LE 12V  
RD700 700 560 636 509 P222LE-S 12V  
RD770 770 616 N/A N/A P222LE-II 12V
RD825 810 740 N/A N/A DP222LC 12V
 
ESP :Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.PRP :Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.