RSC series

GENSET MODEL

ESP
kVA/kW

PRP
kVA/kW

ENGINE MODEL

CYL.

PDF

DESIGN SPECIFICATIONS; High quality, reliable and complate power unit,Compact design,Easy start and maintenance possibility,Every generating set is subjected to a comprehensive test programme which includes full load testing and checking and providing of all control and safety shut down functions testing,Full engineered with a wide range of options and accessories:Canopy,soundproof and on road trailerENGINE; CUMMINS heavy duty diesel engine, Four stroke, water cooled, 1500 rpm, turbocharged, charge air cooled Direct injection fuel system, 24 VDC starter and charge alternator,  Replaceable fuel filter, oil filter and dry element air filter,
Cooling radiator and fan, Starter battery (with lead acid) including Rack and Cables,
Flexible fuel connection hoses and oil sump drain valve, Industrial capacity exhaust silencer and steel bellows, Jacket water heater (at automatic models)
Operation mauals and circuit diagram documents

ALTERNATOR;Brushless, single bearing system, 4 poles, Insulation class H, Standard degree of protection IP21, Self-exciting and self-regulating, Impregnation with tropicalised epoxy varnish, Solid state Automatic Voltage Regulator

BASE FRAME;The complete genset is mounted as whole on a heavy-duty fabricated, steel base frame. Antivibration pads are fixed between the engine/ alternator feet
and the base frame. Base frame design incorporates an integral fuel tank.
The generating set can be lifted or carefully pushed / pulled by the base frame,Lifting eyes allow easy transportation by a crain.  Dial type fuel gauge and drain plug on the fuel tank.

CANOPY;All canopy parts are designed with modular principles. without welding assembly.
Doors on each side. All metal canopy parts are painted by electrostatic.
Exhaust silencer is protected against environment influencespolyester  powder paint.
Thermally insulated engine exhaust system.   Emergency stop push button is installed outside of canopy  Easy lifting and moving  Easy mainteneance and operation

RSC44

44

35

40

32

4BT3.9-G2

4L

 
RSC70

70

56

63

50

4BTA3.9-G2

4L

 
RSC110

110

88

99

79

6BT5.9-G2

6L

 
RSC145

145

120

132

108

6BTAA5.9-G2

6L

 
RSC200

200

165

180

148

6CTA8.3G2

6L

 
RSC275

275

220

248

198

NTA855-G1A

6L

 
RSC350

350

280

315

252

NTA855-G4

6L

 
RSC375

375

300

349

279

KTA19-G2

6L

 
RSC450

450

360

405

324

NTAA855G7A

6L

 
RSC550

550

440

495

396

KTA19-G4

6L

 
RSC688

688

550

625

500

KTAA19-G6A

6L

 
RSC880

880

704

800

640

KTA38-G2B

12V

 
RSC1000

1000

800

900

720

KTA38-G2A

12V

 
RSC1100

1100

880

990

792

KTA38-G5

12V

 
ESP : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.PRP :Applicable for supplying power to varying electrical load for unlimited hours.
PRP : is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.